Panasonic WV-CF294 Security Camera User Manual


 
Direct mounting
If the camera is directly mounted on a
wall/ceiling, align the camera mounting posi-
tion with the position of the hole through
which the cables run and make the hole.
If no hole is made through a wall/ceiling and
open wiring along a wall/ceiling is used,
process the cover so that the cables can be
run through the side of the cover.
11
Installations and Connections
The following installation should be made by qualified service personnel or system installers.
Preparations
Important:
Procure 4 mounting screws according to the material of the installation area. In this case,
wood screws and nails should not be used.
Recommended tightening torque is as follows.
M4: 1.6 N·m {16 kgf·cm}
Required pull-out capacity of a single screw/bolt is 196 N {20 kgf} or more.
If a ceiling board such as plaster board is too weak to support the total weight, the area
shall be sufficiently reinforced.
The protection sheet attached to the dome cover shall be peeled off after installation.
UTP cable access hole ø12 mm {1/2"}
83.5 mm {3-5/16"}
ø129.5 mm {5-1/8"}
4.5 mm
{3/16"}
46 mm {1-13/16"}
<Back/upper>
Cable access hole for wall/ceiling
ø30 - 50 mm {1-3/16" - 2"}
Side cable access hole
Camera fixing hole ø4 - 4.5 mm {3/16"}
Using a two-gang junction box
When using a two-gang junction box (4" x
4"), procure one locally that meets the
dimensions in the figure.
And then, locally procure four camera-
mounting screws suitable for the installation
surface and structure of the wall/ceiling or
two-gang junction box.
Processed section of the side
surface of the cover
Caution:
ONLY CONNECT THIS TO 24 V AC OR 12 V DC CLASS 2 POWER SUPPLY.