Panasonic wv-cp500 Security Camera User Manual


 
22
Camera system setting [SYSTEM SETUP]
Performs the settings relating to the camera system such as synchronization, alarm input/output terminal, and privacy zone.
The following settings can be configured on the "SYSTEM SETUP" screen displayed from the top screen. Refer to page 5 for how
to call up the screen.
10. Synchronization method selection [SYNC]
This unit supports the following 3 types of synchronization methods, and one of the following is selected.
(1) Multiplexed vertical drive signal (VD2)
(2) Synchronization is performed on the basis of the power supply frequency.
(3) Internal synchronization (INT) (default)
Input of a multiplexed vertical drive signal (VD2) automatically switches to the VD2 synchronization even if the camera is set to
other than the VD2 synchronization method.
When other than the VD2 synchronization is selected, either the power supply synchronization or internal synchronization can be
selected.
Note:
• Thepowersupplysynchronization(LL)settingischangeableonlyinthe60Hzareas.Thepowersupplysynchronization(LL)
cannot be setup in the 50 Hz areas.
Setting of the power supply synchronization (LL) mode
The adjusting video signal of the camera and the criterial external synchronizing input signal (power) are connected to a 2-input
oscilloscope and the phase is adjusted.
Note:
• Movementofthecameraorpresenceofaspikenoiseinthepowerlinemaycauseverticalphasechange.Insuchacase,
adjust the phase again.
Follow the procedure below.
**SYSTEM SETUP**
SYNC INT
ALARM IN/OUT
PRIVACY ZONE OFF
STABILIZER OFF
EL-ZOOM OFF
RET TOP END
!0
!1
!2
!3
!4
"SYSTEM SETUP" screen
**SYSTEM SETUP**
SYNC LL
ALARM IN/OUT
PRIVACY ZONE OFF
STABILIZER OFF
EL-ZOOM OFF
RET TOP END
"SYSTEM SETUP" screen "SYNC" screen
**SYNC**
V PHASE
COARSE 1(1--16)
FINE
...
|
...128
- +
RET TOP END