Pelco 1/3-Inch CCD Camera Camera Accessories User Manual


 
8 C1963M (8/04)
AWB – Automatic White Balance
Following are the AWB switch settings:
OFF – Processes the viewed image to retain color balance in a restricted color temperature
range.
ON (Default setting) – Automatically processes the viewed image to retain color balance over
a wide color temperature range.
SYNC – Synchronization
Locks the frame rate to the power supply frequency. Eliminates vertical roll caused by multiple
cameras connected to the same switching device. Each camera output is synchronized to the
frequency of the power supply. Set the camera synchronization mode to one of the following:
OFF (Default setting) – Auto mode, DC internal, AC line lock. For vertical phase adjustment
refer to
LL – Vertical Phase Adjustment.
ON Internal mode, use with noisy AC power.
GAM – Gamma
There are two different levels for gamma. One setting increases the overall contrast of the
scene and the other setting increases visibility in the dark areas of the scene. Set the gamma
level to one of the following:
OFF Linear response increases (overall) contrast.
ON (Default setting) – Increases visibility in dark areas of the picture.
FL – Flickerless
The Flickerless setting can reduce the flicker caused by certain lighting conditions. The
Electronic Sensitivity Control setting must be off for correct operation of the Flickerless
function. Choose between the following settings:
OFF (Default setting) – Disables the Flickerless mode.
ON Enables the Flickerless mode.