Pelco Manual C1405M-E (11/03) 13
ELECTRICAL
Input Voltage: 24, 120 or 230 VAC, 50/60 Hz
Electrical
Connections: One each of the following when equipped with optional circuit
board (O/I-PCB):
3-connector terminal block for power input
6-pin lens connector
9-connector terminal block for lens wiring
10-connector terminal block for camera/lens wiring
2-connector terminal block for spare connections
3-pin socket for camera power input
2-pin socket for optional camera power input
2-pin socket for blower
2-pin socket for defroster
4-pin socket for heaters
Input Power: Heater-1 60 watts
Heater-2 50 watts
Heater-3 55 watts
Defroster 15 watts
Blower 8 watts
MECHANICAL
Construction: Die-cast, extruded, and sheet aluminum
Finish: Polyester powder coat, 2-tone gray
Cable Entry: Two UL-approved glands on bottom of enclosure; maximum
cable diameter 0.47 inch (1.19 cm). Will accept 1/2-inch (1.27
cm) conduit without glands.
Window: Plastic
Window
Viewing Area: 3.50" H x 4.00" W
(8.89 x 10.16 cm)
Camera
Mounting: Removable camera sled that can be inverted to accommodate
various heights of cameras and lenses
Maximum
Camera/Lens
Size: Accommodates camera/lens combinations (including BNC
connector) up to:
EH4718
17" L x 5.5" W x 4.25" H