Pelco Manual C458M-B (1/98) 13
4.0 MAINTENANCE
Regularly scheduled maintenance will prolong the operational life and appearance
of the equipment.
Clean the dome with a nonabrasive cleaning cloth and antistatic cleaner that is safe
for use on acrylic plastic. Do not use kerosene or similar substances that can scratch
the surface.
The dome drive should also be inspected and any dust and debris blown off. Pay
special attention to the spur gear drives. After removing dust and debris a film of
silicone lubricant should be applied to both pan and tilt spur gears for prolonged
gear life. It is recommended that the unit be checked at six-month intervals.
No adjustments are required.
4.1 DOME DRIVE REMOVAL
1. Pendant Models Only - Remove the gasket from the rim of the back box.
2 Remove the back box trim ring or bezel. To remove a bezel, turn it about 1/2"
(1.27 cm) counterclockwise and pull down.
3. Turn off the power.
4. Remove the hairpin clips from the latches.
5. Open one of the latches.
6. Grasp the unit with one hand to prepare for the 10- to 13-pound (4.5 to 5.9 kg)
load.
7. Open the other latch and lower the dome drive.