Pelco DX9116F Security Camera User Manual


 
C635M-A-QS (3/09) 5
SERVER CONFIGURATION UTILITY
To open this application, double-click the DX9000 Server Configuration Utility icon on your recorder’s desktop.
Set the frame rate and resolution. The number of channels is set automatically.
Select the recording format. The default is NTSC.
Click Server Identification to change the computer name (default is Pelco1) and IP address (default is 100.0.0.101).
NOTE: Each recorder must have a unique recorder name and IP address.
Enter the multicast group number. The last three numbers must match the last three numbers of the IP address. The default
is 239.0.0.101.
Click Configure.
Restart the recorder.
Figure 5. Server Configuration Utility