Pelco EH4718L/PSA Security Camera User Manual


 
Pelco Manual C1415M-PSA (12/97) 5
4.0 WINDOW WIPER ADJUSTMENTS
1. Open the enclosure lid.
2. Refer to Figure 2 and set either of the following two options:
a. The time between wiper strokes can be adjusted between 3 and 10 sec-
onds by rotating the potentiometer R8. Turn the adjustment clockwise to
increase the time. The potentiometer only makes one revolution. Turn
power on to make this adjustment.
or
b. The wiper can be set to operate continuously by placing the delay jumper
at JP6 in the OFF position.
3. Close the enclosure lid.
Figure 2. Wiper Circuit Board Component Locations
BLU
WHT
BLK
BLK
BLK/WHT
BLU
BLU/WHT
BRN
BRN/WHT
Transformer
Power input to
PCB9000301
BLK
RED
YEL
GRN
C
NO
NC
_
+
M
Input Input Input
24 VAC 120 VAC 230 VAC
JP1 1 - 2 2 - 3 2 - 3
JP2 1 - 2 2 - 3 1 - 2
JP3 1 - 2 2 - 3 1 - 2
JP4 1 - 2 2 - 3 2 - 3
JP5 1 - 2 2 - 3 2 - 3