Menu ConfigurationRS-485 communication control
Connection
Using a RS-485 communication, it will be able to control the OSD menu at the
SAMSUNG TECHWIN System Controller or DVR.
(1) The case which it controls from the PC
Using a RS-485 converter, It connects to RS-485 control cable outside camera
and serial cable
EX) SERIAL PORT OF THE PC(COM1) SERIAL CABLE RS-485 CONVERTER RS-485
CONTROL CABLE
(2)The case which it controls from the DVR or System Controller
It connects the RS-485 control cable in the connection terminal of 485 control
boards which are connected with the DVR or System Controller.
Connecting to RS-485 Control Cable
• When you construct external control systems for a camera control, please use to
the SAMSUNG TECHWIN PROTOCOL or PELCO-D PROTOCOL.
• When you connecting to RS-485 control cable, please peel off the outer skin
inside the RS-485 control cable.
Notes
CONTROL CABLE SPEC
RED (TRX+) RS-485+
WHITE(TRX-) RS-485-
Setup Menu
LENS • DC
EXPOSURE • SHUTTER • AGC • SENS-UP
• RETURN
WHITE BALANCE • ATW • MANUAL • AWC
SET
• OUTDOOR • INDOOR
BACKLIGHT • OFF • WDR • BLC
SSNR • ON • OFF
DAY/NIGHT • COLOR • B/W • AUTO
IMAGE ADJUSTMENT • FREEZ • V-REV • H-REV
(IMAGE ADJ.) • D-ZOOM • SHARPNESS
• RETURN
SPECIAL • CAMTITLE • MOTION DET • PRIVACY
• DIS • COMM ADJ • LANGUAGE
• RESET • RETURN
EXIT
* RS-485 Communication establishment initial value
485 Control Board Connection Port RS-485 Control Port
(+) CONNECTION TERMINAL RED (TRX+)
(
-) CONNECTION TERMINAL WHITE (TRX-)
Item
Initial value
Camera ID BAUD RATE UART MODE PET PKT
1 9600 8-NONE-1 ENABLE