Sanyo VCC-6570P Camcorder User Manual


 
SETTINGS
External sync adjustment (VBS)
1 Connect the VBS signal output for the other camera to the VBS
IN connector at the rear of this camera.
2 If the signals are not synchronized, change the sub-carrier (SC-P1)
switches as follows.
Setting 9-pin 10-pin
Default OFF (down) OFF
Set to 90˚ counterclockwise OFF ON (up)
Set to 180˚ counterclockwise ON OFF
Set to 270˚ counterclockwise ON ON
Note:
The sub-carrier switches let you make broad adjustments to the
sub-carrier phase. If finer adjustments are required, contact the
place of purchase.
The type and length of the cable which is connected to the VBS
connector may cause the horizontal synchronization being out of
phase. If this happens, adjust VR304 (H-P: horizontal sync).
Lens iris adjustment
If using a DC type auto-iris lens, you will need to set the LEVEL
(VR301) volume when shooting in the conditions described below.
L (counterclockwise): To decrease the contrast
H (clockwise): To increase the contrast
If shooting simultaneously in a dark room and through a bright
window.
If the subject background is extremely bright or dark.
If the brightness of the picture on the monitor is not correct.
109
VR304
H-P
VR301
LEVEL
L53T5/XE GB 2001, 7, 26
English 15