Cheetah 10K.6 FC Product Manual, Rev. B 39
9.1.5 Fibre Channel port login accept
Table 7 identifies the N_Port Login access payload values.
Table 7: N_Port Login Accept (ACC) payload
9.1.6 Fibre Channel Process Login
Table 8 lists the process login payload data.
Table 8: Process Login (PLRI) payload
XX Indicates fields that are not used.
9.1.7 Fibre Channel Process Login Accept
Table 9 lists Cheetah 10K.6 FC process login accept payload data.
Table 9: Process Login Accept (ACC) payload
Bytes
0-15 02 00 00 00 20 20 00 00 88 00 FS FS 00 FF 00 01 Common
16-31 000001F420PP002037UIUIUI20000020
32-35 37 UI UI UI
36-47 000000000000000000000000Class 1
48-51 00 00 00 00
52-63 000000000000000000000000Class 2
64-67 00 00 00 00
68-79 800000000000FSFS00FF0000Class 3
80-83 00 01 00 00
84-95 000000000000000000000000Reserved
96-99 00 00 00 00
100-111 000000000000000000000000Vendor -
112-115 00 00 00 00 Version
FS Receive buffer field size. The drive returns and uses the receive buffer size from the N_Port Login Class 3 receive
buffer.
UI Unique identifier. This 24-bit field is uniquely assigned to the drive. This same UI appears in the Port Name and
Node Name fields.
PP Port identifier field.
01 P_LOGI received on Port A.
02 P_LOGI received on Port B.
Bytes
0-15 20 10 00 14 08 00 20 00 XX XX XX XX XX XX XX XX
16-19 00000022
Bytes
0-15 02 10 00 14 08 00 21 00 00 00 00 00 00 00 00 00
16-31 00000012