Sony BRC-Z300 Camcorder User Manual


 
8
VISCA Camera-Issued Messages
ACK/Completion Messages
z = Device address + 8
Error Messages
Network Change Message
Command Command Message Comments
ACK z0 4y FF
(y: Socket No.)
Returned when the command is accepted.
Completion z0 5y FF
(y: Socket No.)
Returned when the command has been executed.
Command Command Message Comments
Syntax Error z0 60 02 FF Returned when the command format is different or when a command with
illegal command parameters is accepted.
Command Buffer Full z0 60 03 FF Could not accept a command that is received while two commands are
currently being executed (two sockets have been used).
Command Canceled z0 6y 04 FF
(y: Socket No.)
Returned when a command which is being executed in a socket specified by
the cancel command is canceled. The completion message for the command
is not returned.
No Socket z0 6y 05 FF
(y: Socket No.)
Returned when no command is executed in a socket specified by the cancel
command, or when an invalid socket number is specified.
Command Not Executable z0 6y 41 FF
(y: Socket No.)
Returned when a command cannot be executed due to current conditions.
For example, when a command for controlling the manual focus is received
during the auto focus mode.
Command Command Message Comments
Network Change z0 38 FF Issued when power is supplied to the camera.