Sony DSR-450WSL/450WSPL Camcorder User Manual


 
85
Menu Organization and Operation
Chapter 5 Menu Displays and Detailed Settings
BLACK
SHADING
BLK SHAD CH SEL R/G/B R Selects the channel adjusted by this
menu.
A P
R/G/B BLK H SAW (–99 to 99) 0 Compensates horizontal Saw black
shading.
P
R/G/B BLK H PARA Compensates horizontal Parabola
black shading.
R/G/B BLK V SAW Compensates vertical Saw black
shading.
R/G/B BLK V PARA Compensates vertical Parabola black
shading.
BLACK SAW/PARA OFF/ON ON Turns black shading Saw and
Parabola compensation on and off.
St
MASTER BLACK (–99 to 99) 0 Adjusts the master black level. A P Sc R St
MASTER GAIN
(TMP)
–3dB/0dB/3dB/
6dB/9dB/12dB/
18dB/24dB/
30dB/36dB
Depends
on the
switch.
Temporarily adjusts the master gain
value.
BATTERY <Sony Info>
BEFORE END 1 5 to 100%
(in 5% steps)
5% When a BP-GL65/GL95 Battery Pack
is used, sets the voltage warning level
just before the battery ends.
A P
END 1 0 to 5%
(in 1% steps)
0% When a BP-GL65/GL95 Battery Pack
is used, sets the voltage level at
which the battery ends and the
camcorder stops operation, just
before the battery ends.
<Sony>
BEFORE END 2 11.5 to 17.0V
(in 0.1V steps)
11.5V -– When a BP-L60S Battery Pack is
used, sets the voltage warning level
just before the battery ends.
A P
END 2 11.0 to 11.5 V
(in 0.1V steps)
11.0V When a BP-L60S Battery Pack is
used, sets the voltage level at which
the battery ends and the camcorder
stops operation, just before the
battery ends.
<Others, EXT DC>
BEFORE END 3 11.5 to 17.0V
(in 0.1V steps)
11.8V When a battery pack other than a BP-
GL65/GL95/L60S or an external
power connected to the DC IN
connector is used, sets the voltage
warning level just before the battery
ends.
A P
END3 11.0 to 14.0 V
(in 0.1V steps)
11.0V When a battery pack other than a BP-
GL65/GL95/L60S or an external
power connected to the DC IN
connector is used, sets the voltage
level at which the battery ends and
the camcorder stops operation, just
before the battery ends.
Page Item Settings Default USER
menu
Description File