Speco Technologies CNC5915DNVW Security Camera User Manual


 
- 15 -
EXPOSURE
SENS-UP
SHUTTER
AGC
SENS-UP
BLC
D-WDR
RETURN
SENS-UP
RETURN
AUTO
MIDDLE
AUTO
OFF
OFF
RET
x 4
NOTE
*Shutter: Select Shutter using the Up or Down button, you can adjust the shutter speed
from 1/60, FLK, 1/250~1/100,000.
FLK: Select FLK mode if flickering occurs; caused by the unmatched frequency of electric
light. If select FLK mode, sense-up does not operate.
* AGC(AUTO GAIN CONTROL):
A higher gain increases brightness but also increases any noise.
OFF : Deactivates the AGC function
LOW : Sets automatic gain control to LOW.
MIDDLE : Sets automatic gain control to MIDDLE.
HIGH : Sets automatic gain control to HIGH
* SENS - UP:
At night and/or in dark conditions, the Sens-Up mode can be selected to desired value from x2 ~ x256.