B-2. DOME SET - RECOVER
This feature allows the dome to work from the last setting before you use the dome manually
(Auto scan, group tour, pattern or sectors) , after the set time, even power shut down and it turns
on again. Recovery time can be programmed from 15 second to 90 seconds. The default
setting is OFF.
B-3. DOME SET - MANUAL SPEED
Manual Speed of Pan/Tilt is selectable from 10°/sec up to 200°/sec. The default setting is
100°/sec
B-4. DOME SET - AUTO FLIP
Auto Flip is available and the default setting is OFF. Move joystick “right or left” to select ON or
OFF. The default setting is OFF. This function can be recalled by pushing 67+ preset button.
B-5. DOME SET – ZOOM SPEED
Zoom speeds are selectable FAST or SLOW mode. Move joystick to the right direction for
selecting FAST or SLOW. The default setting is FAST.
B-6. DOME SET – ALARM
All alarms are available when set to the ENABLE Mode. Move joystick in the right or left direction
to select ENABLE/DISABLE. The default setting is DISABLE. This function can be recalled by
pushing 97 + preset button.
B-7. DOME SET - LANGUAGE
Multiple languages are selectable here. Move the joystick to the right or left direction to select a
language. The default setting is ENGLISH.
B-8. DOME SET – [NEXT PAGE]
B-8-1. DOME SET – [NEXT PAGE] – SYSTEM LOCK
Password protection maintains memorized data. It cannot be adjusted by anybody without the
correct password. In order to enter [PASSWORD] page, system lock status is must set as ON.
Move joystick to right or left direction to select ON. The default setting is OFF.