Unibrain 501 Digital Camera User Manual


 
Unibrain Fire-i 501/511/601/701/702/810 Operation Manual Page 43
3.13. Strobe Delay / Duration Table
The table shows the strobe index by increment step through the strobe delay time and the strobe duration time. The
Increment Step is different according to strobe index. Fire-i 501/511/601 and Fire-i 701/702/810 have different range
for strobe delay and duration in the index table.
Fire-i 501/511/601
Strobe Delay/Duration Table
Strobe Index(Y) Increment Step
Strobe Dela
y
Time : T
Delay Time Duration Time Range
0 0us N.A
1 1us N.A
2 2us 2us
3~250 1us
T
=Y us
T
=Y us 3us~250us
251~489 250us
T
=
(
Y-250
)
*250us+250us
T
=
(
Y-250
)
*250us+250us 500us~60ms
Strobe Delay/Duration Index Strobe Delay Time Strobe Duration Time
0 0us N.A
1 1us N.A
2 2us 2us
10 10us 10us
100 100us 100us
250 250us 250us
253 1ms 1ms
257 2ms 2ms
269 5ms 5ms
289 10ms 10ms
329 20ms 20ms
449 50ms 50ms
489 60ms 60ms
Fire-i 701/702/810
Strobe Delay Table
Strobe Index(Y) Increment Step
Strobe Dela
y
T
ime : T
Delay Time Range
0
1us
0us 0us
1 1us 1us
2 2us 2us
3~250
T
=Y us 3us~250us
251~3900
T
=Y us 251us~3900us