Unibrain Fire-i 501/511/601/701/702/810 Operation Manual Page 44
Strobe Duration Table
Strobe Index(Y) Increment Step
Strobe Duration Time : T
Duration Time Ran
g
e
0 N.A N.A N.A
1 N.A N.A N.A
2 1us 2us 2us
3~250 1us
T
=Y us 3us~250us
251~489 250us
T
=
(
Y-250
)
*250us+250us 500us~60ms
Delay Index(Y) Strobe Delay Time
Duration Index (Y) Strobe Duration Time
0 0us 0 N.A
1 1us 1 N.A
2 2us 2 2us
10 10us 10 10us
100 100us 100 100us
200 200us 250 250us
300 300us 253 1ms
500 500us 257 2ms
800 800us 269 5ms
1000 1000us 289 10ms
2000 2000us 329 20ms
3000 3000us 449 50ms
3900 3900us 489 60ms