A SERVICE OF

logo

installation and user information
updating software
Chapter 2 51
Add /var/opt/ignite/sps/sv6_files to path.
Verify sv6_targets list.
all touch /var/adm/sw/.sdkey
all /usr/sbin/swacl -l root -M user:root@svm:crwit
swcopy
swinstall
step 1: preparation
1. Back up your system before installing a patch.
2. Login as root.
3. Add the sv6files directory to your path to access helpful scripts.
Example:
export PATH=$PATH:/var/opt/ignite/sps/sv6files
4. Download software to a temporary directory on the master node.
Example:
Save As /tmp/PHSS_25612
Before installing, observe any special instructions or patch
dependencies.
Individual HP-UX patches are available at http://itrc.hp.com
5. Unpack compressed packages if necessary.
Example:
cd /tmp
sh PHSS_25612
6. Set root access permissions for SD (Software Distributor) tools.
Verify that you have a recent version (PHCO_23966, PHCO_25875,
or newer) of the software distributor tools, which have the ability to
install to multiple targets.
swlist |grep SD