A SERVICE OF

logo

OPERATION
B-20 B-20
POWER WAVE 450
Trigger
Position
1
GMAW GMAW STICK
1
Pulse GMAW
Pulse FCAW FCAW
WFS DISPLAY: WFS DISPLAY:
Wire Feed Speed Wire Feed Speed
WFS and WFS and Preset VOLTAGE VOLTAGE
Open Arc Length Trim Preset Voltage Current DISPLAY: DISPLAY:
Arc Length Trim Preset Voltage
WFS, WFS, WFS DISPLAY: WFS DISPLAY:
Actual Arc Actual Arc Preset Current, Wire Feed Speed Wire Feed Speed
2
Closed Voltage, Voltage, Actual Arc VOLTAGE VOLTAGE
Actual Arc Actual Arc Voltage, Actual DISPLAY: DISPLAY:
Current Current Arc Current Actual Arc Voltage Actual Arc Voltage
1
In Stick, trigger is on Remote Control Kit K941-1.
2
Arc Current, not wire feed speed, is displayed if a Remote Control Kit is attached to the wire feeder.
Power Wave 450
Wire Feeder
In Pulse processes:
The wave control adjustment allows the frequency
setting to vary. Increasing the wave control allows the
frequency setting to increase, and decreasing the
wave control allows the frequency setting to
decrease. Varying the wave control setting affects the
droplet trans-fer and allows fine-tuning for different
welding positions.
In GMAW and FCAW processes:
The wave control adjusts the inductance. (Inductance
is inversely proportional to pinch.) Increasing the
wave control setting decreases the inductance, which
results in the arc getting colder and pinched tighter.
Decreasing the wave control setting increases the
induc-tance, which results in the arc getting wider.
In Stick processes:
The wave control adjusts the arc force. Increasing the
wave control setting increases the arc force, making
the arc more harsh but less likely to stick. Decreasing
the wave control setting decreases the arc force,
making the arc softer and smoother.
Adjustable GMAW GMAW
Parameters Pulse FCAW Stick
Wire Feeder Wire Feed Wire Feed
WFS Display Speed Speed
Wire Feeder Arc Length Preset
Voltage Display Trim Voltage
Power Wave 450 Display
(with GMAW Pulse, Wave Wave Wave
GMAW FCAW, Stick Control Control Control
Process Selection Overlay) (Frequency) (Inductance) (Arc Force)
TABLE B.3 – ADJUSTBLE PARAMETERS
TABLE B.4 – DISPLAYS OF THE POWER WAVE AND WIRE FEEDERS
FOR DIFFERENT PROCESSES IN BOTH TRIGGER POSITIONS