POWER WAVE 450
TECHNICAL SPECIFICATIONS - POWER WAVE 450
INPUT - THREE PHASE 50/60 HZ. ONLY
Input Voltages: 200 230 400 460 575
Input Currents
@ 500A/40 VDC 87 76 44 38 32
@ 450A/38 VDC 75 65 38 32 28
RATED OUTPUT
Duty Cycle Amps Volts at Rated Amperes
200 - 60% Duty Cycle 500 40 VDC
230/400/460 - 60% Duty Cycle 500 40 VDC
460/575 - 60% Duty Cycle 500 40 VDC
200 - 100% Duty Cycle 450 38 VDC
230/400/460 - 100% Duty Cycle 450 38 VDC
460/575 - 100% Duty Cycle 450 38 VDC
OUTPUT
Constant Open Continuous Process
Cir
cuit Volta
ge Current Range Current Ranges
75 Volts 5-540 Amps GMAW 50-540 Amps
FCAW 40-540 Amps
STICK 30-540 Amps
Pulse Pulse Pulse and Background Pulse
Current Range Voltage Range Time Range Frequency
5-750 Amps 5-55 Volts 100 Microsec - 3.3 Sec 0.15 - 1000 Hz
RECOMMENDED INPUT WIRE AND FUSE SIZES
Type 75°C Type 75°C Type 75°C
Input Duty Input Ampere Copper Wire in Ground Wire in (Super Lag)
Voltage/ Cycle Rating on Conduit Conduit or Breaker
Freqency Nameplate AWG[IEC] AWG[IEC] Size (Amps)
Sizes (MM
2
) Sizes (MM
2
)
200/50-60 60% 87 4 (25) 8 (10) 120
230/50-60 60% 76 4 (25) 8 (10) 100
400/50-60 60% 44 8 (10) 10 (6) 50
460/50-60 60% 38 8 (10) 10 (6) 50
575/50-60 60% 32 8 (10) 10 (6) 50
200/50-60 100% 75 4 (25) 8 (10) 100
230/50-60 100% 65 4 (25) 8 (10) 100
400/50-60 100% 38 8 (10) 10 (6) 50
460/50-60 100% 32 8 (10) 10 (6) 50
575/50-60 100% 28 8 (10) 10 (6) 40
PHYSICAL DIMENSIONS
Height Width Depth Weight
905 mm 515 mm 1010 mm 138 kg
35.6 in. 20.3 in. 39.8 in. 304 lbs.
OPERATING TEMPERATURE RANGE STORAGE TEMPERATURE RANGE
0° to 40°C -50° to 85°C
INSTALLATION
A-1 A-1