2. MACHINING PARAMETERS
2.1 Process Parameters
II - 3
2. MACHINING PARAMETERS
The number of digits in the decimal section of the parameters related to length is determined by the input setting
unit.
The input setting unit is set with parameter "#1003 iunit".
Input setting unit No. of digits in decimal section Example of setting range
B 3 0 to 999.999 (mm)
C 4 0 to 99.9999 (mm)
2.1 Process Parameters
<WRK COUNT> (No. of workpieces machined)
# Item Contents Setup range (unit)
8001 WRK COUNT M Set the M code that counts the No. of workpiece
repeated machining.
The No. will not be counted when set to 0.
0 to 99
8002 WRK COUNT The current machining No. is displayed. Set the
initial value.
0 to 999999
8003 WRK LIMIT Set the maximum No. of workpieces machined.
A signal is output to PLC when the No. of machining
times is counted to this limit.
0 to 999999
<AUTO TLM> (Automatic tool length measurement)
# Item Contents Setup range (unit)
8004 SPEED Set the feedrate during automatic tool length
measurement.
1 to 60000 (mm/min)
8005 ZONE r Set the distance between the measurement position
and deceleration start point.
0 to 99999.999 (mm)
8006 ZONE d Set the tolerable zone of the measurement position.
If the sensor signal turns ON in front of d before the
measurement position‚ or if the signal does not turn
ON after d is passed‚ an alarm will occur.
0 to 99999.999 (mm)
<AUTO CORNER OVR> (Automatic corner override)
# Item Contents Setup range (unit)
8007 OVERRIDE Set the override value for automatic corner override. 0 to 100 (%)
8008 MAX ANGLE Set the max. corner opening angle where
deceleration should start automatically.
If the angle is larger than this value‚ deceleration will
not start.
0 to 180 (°)
8009 DSC. ZONE Set the position where deceleration starts at the
corner.
Designate at which length point before the corner
deceleration should start.
0 to 99999.999 (mm)