X10 PROGRAMMING OPTIONS
OutletLinc is X10 ready, meaning that it can respond to X10 commands from X10 controllers. However, to
operate OutletLinc in X10 mode, you must first set up an X10 address. As it ships from the factory or after
a factory reset procedure, OutletLinc will have not have an X10 address set up.
Setting the X10 Primary Address
1) Set OutletLinc to Linking Mode by pressing & holding the Set button for 3 seconds
The OutletLinc Status LED will begin blinking
You will have 4 minutes to complete the next step before Linking Mode automatically times out.
2) Using an X10 controller, send the X10 address you want to assign and the ON command three times
For example, to assign the address A1, you would send “A1 ON A1 ON A1 ON.”
3) Once OutletLinc has received the sequence, it will exit Linking Mode
The OutletLinc Status LED will stop blinking and turn on solid
Removing the X10 Primary Address
If you are no longer going to control OutletLinc with an X10 address, it is very important that you Unlink it.
Otherwise, OutletLinc will still respond to X10 commands and may cause OutletLinc to turn on by itself.
1) Set OutletLinc to Linking Mode by pressing & holding the Set button for 3 seconds
The OutletLinc Status LED will begin blinking
2) Set OutletLinc to Unlinking Mode by pressing & holding the Set button for 3 seconds again
The OutletLinc Status LED will continue blinking
You will have 4 minutes to complete the next step before Unlinking Mode automatically times out.
3) Using an X10 controller, send the X10 address you wish to remove and the ON command three
times
For example, to remove the address A1, you would send “A1 ON A1 ON A1 ON”.
4) Once OutletLinc has received the sequence, it will exit Unlinking Mode
The OutletLinc Status LED will stop blinking and turn on solid