English
©TitanToolInc.Allrightsreserved. 3
Maintenance
Follow all safety precautions as described in the Safety
Precautions section of this manual before proceeding.
NOTE: Refer to the Parts List section in this manual for part
identication.
Replacing/Servicing the Seal Assembly
Ifyourspraygunleaksorspitsatthetipwhenyoureleasethetrigger,the
needleorseatisworn,damaged,ordirtyandmustbereplacedorcleaned.
Never attempt to perform maintenance on the spray gun
without first performing the “Pressure Relief Procedure.”
1. Disconnectthesprayhosefromthegun.
2. Removethetipandtipguard.
3. Withthetriggerdepressed,removethediuserandthecopper
washer from the front of the gun housing.
4. Removetheheadscrew,triggerpivotscrew,andtrigger.
5. Removetheplugfromtherearofthegunhousing.
6. Inserttherepairtoolintothepassageattherearofthegunhousing,
andforcethesealassemblyoutthroughthefrontofthegun.
NOTE: If a repair tool is not available, remove one of the screws
from the bottom of the gun handle and use it to tap on the
back of the seal assembly.
7. Lubricatetheo-ringsonthenewsealassembly.
8. Installthenewsealassemblyintothefrontofthegunhousing.Using
theopenendoftherepairtool,forcethesealassemblycompletely
intothegunhousing.Pushontheballatthefrontoftheseal
assemblytoensurecompleteinsertion.
9. Reattachthetrigger,triggerpivotscrew,andheadscrew.
10. WIththetriggerdepressed,installthecopperwasherfollowedbythe
diuserintothefrontofthegunhousingandtightensecurelywitha
wrench.
11. Performthe“AdjustingtheSealAssembly”proceduredescribed
below.
Adjusting the Seal Assembly
Proper adjustment of the seal assembly is essential to ensure
positive shut-off when the trigger is released.
1. Pull the trigger.
2. Insertaatheadscrewdriverintothepassageattherearofthegun
housinguptothesealassembly.
3. Threadtheplugintothepassageattherearofthegunhousingand
tighten securely.