Water hardness Adjusting the water hardness
setting
Use of salt
Clarke °TH mmol/l manually electronically
46 - 52 65 - 75 6,5 - 7,5 2 level 8 yes
36 - 45 51 - 64 5,1 - 6,4 2 level 7 yes
28 - 35 40 - 50 4,0 - 5,0 2 level 6 yes
23 - 27 33 - 39 3,3 - 3,9 2 level 5 yes
18 - 22 26 - 32 2,6 - 3,2 1 level 4 yes
13 - 17 19 - 25 1,9 - 2,5 1 level 3 yes
5 - 12 7 - 18 0,7 - 1,8 1 level 2 yes
< 5 < 7 < 0,7 1 level 1 no
The water softener must be set in both ways:
manually, using the water hardness dial and
electronically.
Setting the water softener manually (see table)
Set switch to position 1 or
2
The water softener is factory set at position 2.
Setting the water softener
electronically (see table)
1. Press the On/Off button. The appliance
must be in setting mode.
2.
Press and hold Programme selection/
Cancel button until programme light A
flashes and programme light B illuminates
with fixed light.
3. After a few seconds:
–
programme light B turns off
–
programme light A goes on flashing
–
End of programme light starts flashing:
the number of flashes corresponds to
current level set. The flashing is repea-
ted with a pause of a few seconds.
Examples: 5 flashes, pause, 5 flashes,
pause, etc... = level 5.
10