Triggering during the Readout State
o For applications requiring the fastest triggering cycle time whereby the camera
image sensor is exposing and reading out simultaneously, then the User Trigger
signal should be applied as soon as a valid Trigger Ready is detected.
o In this case, Trigger Latency and Trigger Jitter can be up to 1 line time since
Exposure must always begin on an Interline boundary.