Axis Communications 290A Security Camera User Manual


 
5
290A Installation Instructions
Connecting the camera
Warning: Be sure to work inside the housing in dry conditions. Rain water, moisture and prolonged con-
densation inside the housing may cause serious damage to the camera and disturb the picture quality when
in operation.
Warning: High voltage - the apparatus works on 100-240VAC. Always ensure that the power is discon-
nected before starting any work or opening the housing.
1. Open the housing by releasing the two clips on the side.
2. Strip back the mains power cable by 5mm. The minimum mains cable conductor area
for installation of the housing is 0.5 mm
2
.
Warning: Regulations relating to other parts of the system may require a bigger conductor area. You are
responsible that the requirements of these regulations are met.
3. Route the power cable through the
cable tie (14). Wire into the fused
terminal block (15) as follows:
Blue = neutral (N),
Brown = live (L),
Green/yellow = earth.
Refer to the wiring diagram below.
Wiring diagram 290A
Caution: Ensure that all wires are
correctly and securely wired into the
terminal block (15). No bare wires
should be showing. Tighten the cable
tie (14) so that the power cable is
held firmly.
4. All models - attach an RJ45 connector (not supplied) to the network cable allowing
sufficient cable to reach the back of the camera. Once you have fitted the connector,
plug it into the network connector at the back of the camera.
Important: Only a 90° BNC angle plug will fit inside the housing. Do not use any
other plugs!
14
15
5A, 250V
Fuse