Axis Communications F44 Security Camera User Manual


 
AXIS F44 Main Unit
Hardware Overview
Note
The Status LED can be congured to be unlit during normal operation. To congure, go to Setup > System Options > Ports
& Devices > LED. See the online help for more information.
The Status LED can be congured to ash while an event is active.
The Status LED can be congured to ash for identifying the unit. Go to Setup > System Options > Maintenance .
The Network LED can be disabled so that it does not ash when there is network trafc. To congure, go to Setup > System
Options > Ports & Devices > LED. See the online help for more information.
Shorten Sensor Unit Cable
The sensor unit is delivered with a cable. To shorten the cable follow these steps:
1. Cut the cable to the desired length. Measure from the sensor unit.
2. Strip the plastic outer coating from the end of the cable.
3. Peel back the shield.
4. Flatten the colored wires in the order described below.
1
Brown
2
White/brown
3
Not used
4
Not used
5
White/blue
6
Blue
5. Insert the wires all the way into a shielded 6P6C RJ12 connector.
NONO
NO
TICETICE
TICE
Make sure that the wires stay in the correct order and that the cable shield makes good contact with the connector shield.
6. Use a crimping tool to fasten the connector to the cable.
14 mm 14 mm