1UNPACKING
This electronic equipment should be unpacked and
handled carefully.
Check for the following items:
•Verify the unit model number
•Verify that parts listed as follows have been
included. See INSTALLATION.
Hardware Kit
Quantity Part Description
3 Cable Tie
2BHCS, 1⁄4-20 x 1⁄4in.
1BHCS, 1⁄4-20 x 5⁄8in.
1BHCS, 1⁄4-20 x 3⁄4in.
1BHCS, 1⁄4-20 x 1⁄2in.
1BHCS, 1⁄4-20 x 3⁄8in.
1BHCS, 1⁄4-20 x 11⁄4in.
2 0.4mm (0.016in.) Plastic Spacer
11.65mm (0.065in.) Plastic Spacer
1 3.9mm (0.154in.) Plastic Spacer
17.4mm (0.292in.) Plastic Spacer
1 9.8mm (0.385in.) Plastic Spacer
1 3⁄8in. NPT Plug
2Pull Seals
If an item appears to have been damaged in shipment,
replace it properly in its carton and notify the shipper.
If any items are missing, notify your Bosch Security
Systems Inc. Sales Representative or Customer Service.
The shipping carton is the safest container in which the
unit may be transported. Save it for possible future use.
2SERVICE
If the unit ever needs repair service, the customer
should contact the nearest Bosch Security Systems, Inc.
Service Center for return authorization and shipping
instructions.
Service Centers
USA
Phone: 800-366-2283 or 717-735-6638
fax: 800-366-1329 or 717-735-6639
CCTV Spare Parts
Phone: 800-894-5215 or 408-956-3853 or 3854
fax: 408-957-3198
e-mail: BoschCCTVparts@ca.slr.com
Canada
Phone: 514-738-2434
Europe, Middle East & Asia Pacific Region
Phone: 32-1-440-0711
For additional information, see
www
.boschsecuritysystems.com.
3 CARE AND MAINTENANCE
Clean the viewing window as needed with a mild,
nonabrasive detergent in water and a soft cloth.
4DESCRIPTION
The LTC 9384 Series of environmental housings are
attractive aluminum enclosures designed for outdoor
CCD camera installations.
4.1 Enclosure Rating
4.1.1 NEMA-3R and IP54
The LTC 9384 Series Housings include a breather hole
in the front face cap. The breather hole prevents the
accumulation of moisture inside the housing when
installed in areas of high humidity. With the breather
hole open, the LTC 9384 Series Housings meet the
enclosure rating requirements of NEMA-3R and IP54.
4.1.2 NEMA-4 and IP65
For installations requiring an enclosure rating of
NEMA-6P or IP68, the breather hole must be plugged
using the pull seal (Part No. 315 2569 001) provided in
the hardware kit. Refer to Final Assembly under
INSTALLATION for proper installation.
5INSTALLATION
Qualified service persons should handle this
installation. Installation must conform to all
local codes.
5.1 Model Designation
Power Transformer
1
Model Rated Voltage Voltage Nominal
No. Input Range Output Power
1
LTC 9384/60 115VAC, 108 to 132 24VAC, 30W
50/60Hz 50/60Hz
LTC 9384/20 24VAC, 21.6 to 26.4 24VAC, 30W
50/60Hz 50/60Hz
LTC 9384/50 230VAC, 207 to 253 24VAC, 30W
50/60Hz 50/60Hz
LT C 9384/20NT 24VAC, 21.6 to 26.4 —— 30W
50/60Hz
1
The power transformers included with these housings are used to
provide heater power and can be used to provide isolated camera
power.
2
Heater requires 10 watts.
Do Not Exceed 30VAC Input on 24VAC models.
Operation above 30VAC violates low voltage operation