Bosch Appliances NBN-733 Security Camera User Manual


 
36 en | Troubleshooting DINION HD
AM18-Q0614 | v1.0 | 2012.09 Installation Manual Bosch Security Systems
No audio
transmission to
remote station.
Hardware fault. Check that all connected
audio units are operating
correctly.
Faulty cable connections. Check all cables, plugs,
contacts and
connections.
Incorrect configuration. Check audio parameters
on the Audio
configuration and
LIVEPAGE Functions
pages.
The audio voice
connection is already in
use by another receiver.
Wait until the connection
is free and then call the
sender again.
The unit does not
report an alarm.
Alarm source is not
selected.
Select possible alarm
sources on the Alarm
sources configuration
page.
No alarm response
specified.
Specify the desired alarm
response on the Alarm
connections
configuration page; if
necessary change the IP
address.
Control of cameras
or other units is not
possible.
The cable connection
between the serial
interface and the
connected unit is not
correct.
Check all cable
connections and ensure
all plugs are properly
fitted.
The interface parameters
do not match those of the
other unit connected.
Make sure that the
settings of all units
involved are compatible.
Malfunction Possible causes Solution