Bosch Appliances X40 SN Security Camera User Manual


 
80 en | Configuration Using a Web Browser VideoJet X40 SN
DOC | V4.0 | 2009.06 Installation and Operating Manual Bosch Security Systems
5.37 Advanced Mode: COM1
You can configure the serial interface parameters (orange terminal block) to meet your
requirements.
Serial port function
Select a controllable unit from the list. If you wish to use the serial port to transmit
transparent data, select Transparent. Select Terminal if you wish to operate the unit from a
terminal.
Camera ID
If necessary, enter the ID of the peripheral you wish to control (for example a dome camera or
pan/tilt head). The entered ID relates to the peripheral that is connected to the first video
input. For further video inputs, the ID is automatically counted up and assigned to the
peripheral connected to it.
Baud rate
Select the value for the transmission rate in bps.
Data bits
The number of data bits per character cannot be changed.
Stop bits
Select the number of stop bits per character.
Parity check
Select the type of parity check.
i
NOTICE!
If the VideoJet X40 SN is working in multicast mode (see Section 5.40 Advanced Mode:
Multicasting, page 86), the first remote location to establish a video connection to the unit is
also assigned the transparent data connection. However, after about 15 seconds of inactivity
the data connection is automatically terminated and another remote location can exchange
transparent data with the unit.
i
NOTICE!
After selecting a unit, the remaining parameters in the window are set automatically and
should not be changed.