CHAPTER 11 TROUBLESHOOTING
COPYRIGHT
©
1999 CANON INC. CANON PC800s/900s REV.0 AUG. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
11-43
3. AE Adjustment
Perform this adjustment if you have replaced any of the following:
DC controller PCB
Composite power supply PCB (See p.11-41.)
AE sensor PCB
Scanning lamp
Making Adjustments
Before Starting the Work
• Obtain a newspaper with more or less even print. (Avoid ones with many photos or large
display text.)
Obtain five sheets of white sheets of paper.
Be sure that the intensity of the scanning lamp has been adjusted when you have replaced the
scanning lamp.
Set the density correction switch (SW101) to the middle setting. If the machine is not
equipped with a density correction switch, set the density adjusting lever to the middle set-
ting.
1) Short JP103 and JP104 on the DC controller PCB.
Figure 11-265
2) While keeping the condition in step 1), turn on the power.
The scanning lamp will turn on, and the main motor (M1) will rotate.
3) Stop shorting JP103 and JP104.
JP104
JP103
SERVICE