IRIS AGC BLC SYNC
DC OFF ON INT
AES ON OFF L.L.
1234
DIP Switch Setup: Black and White Cameras
(Factory settings shown. Do not change settings except for BLC function as needed)
DC DC Iris
1 Iris
AES Auto Electronic Shutter
Auto Gain Control
ON Gain level to be fixed at min.
2
(AGC)
OFF Set to this position to improve camera sensitivity in low light conditions
Back Light
ON Set to this position when a strong light is in the background
3
Compensation (BLC)
OFF Normal position
INT Internal synchronization mode
4 Synchronization Mode