2-4
Cisco Video Surveillance 5010/5011 Indoor Fixed HD IP Dome Camera User Guide
OL-22669-02
Chapter 2 Installation
Surface Installation
Surface Installation
Warning
Remove the foam insert from the back box before installing the system. The foam is inserted to secure
the tilt ring; preventing damage to the optical chassis during shipment.
Step 1 Prepare the mounting surface:
a. Using the surface mount ring as a template, drill holes for the mounting hardware. Prepare the
ceiling as follows:
–
Standard ceiling: When mounting the dome camera to a standard ceiling, use either 6-32 toggle
bolts (not supplied)
or #8 x 3.50-inch self-tapping screws (not supplied).
–
Concrete ceiling: When mounting the dome camera to a concrete system, use 8-32 studs and
nuts (not supplied).
b. Drill a hole in the ceiling for wiring.
c. Pull all wiring through the hole and terminate all wires (if not already terminated).
d. Attach the surface mount ring to the mounting surface.
Step 2 Install the lens on the back box:
Note Megapixel lenses are designed and tested to deliver optimal image quality to megapixel cameras.
A standard definition lens installed on a megapixel camera will limit the resolution of the camera
and create poor image quality.
a. Remove the cover from the lens mount.
b. Screw the lens onto the lens mount. Be careful to prevent dust from entering the space between the
lens and the imager. If necessary, use clean, compressed air to remove any foreign matter (refer to
the instructions shipped with the lens). Make sure the lens does not touch the camera imager when
installed.
c. Connect the auto iris lens to the 4-pin connector located on the side of the camera. Pin connections
for the iris drive connector are as follows:
Figure 2-4 Lens Pin Connections
Pin DC (AID) Auto Iris Lens
1 Control coil negative (–)
2 Control coil positive (+)
3 Drive coil positive (+)
4 Drive coil negative (–)
3
12
4
278768