4.4.2.8.3 SYNC
There are two SYNCHRONIZATION modes: INTERNAL and EXTERNAL
LINE-LOCK. In LINE-LOCK mode, without a synchronous generator, it
synchronizes the video signal between cameras. The Line-Lock synchronization is
only used in the places of 60Hz (NTSC models) or 50Hz (PAL models).
-INT: Internal synchronization
-LL: External line-lock synchronization
=> If you choose “LL”, you can adjust the phase your wish to set. Then press the
mini-joystick. You can adjust the phase you wish to set from 0 to 359.
4.4.2.8.4 MOTION DETECTION
EAN850A enables you to observe movements of objects in 4 different places on
the screen, the message “MOTION DETECTED” appears on the screen when
movement is detected; therefore this helps to improve supervision efficiency. The
camera detects an object’s movement by sensing discrepancy of outline.
1) Please direct the arrow to point to “MOTION DET” by using the UP or
DOWN button.
2) Select “ON” by pressing the LEFT or RIGHT button.
3) Press SET button.
z Please select the area you would like to detect from the 4 areas in AREA SEL
mode.
z Please select ON mode for the chosen area.
MOTION DETECTION
> AEREA SEL AREA1
AREA STATE ON
TOP |+++++++++| 10
DOWN |+++++++++| 25
LEFT |+++++++++| 20
RIGHT |+++++++++| 40
Press SET to return
SPECIAL
CAMERA ID OFF
COLOR ADJ. <┘
SYNC. INT
> MOTIION DET ON <┘
PRIVACY OFF
MIRROR OFF
SHARPNESS ON <┘
RESET
RETURN <┘
SPECIAL
CAMERA ID OFF
COLOR ADJ. <┘
> SYNC. LL <┘
MOTIION DET OFF
PRIVACY OFF
MIRROR OFF
SHARPNESS ON <┘
RESET
RETURN <┘
SYNC
> PHASE |++++++++| 0