EverFocus EDN850H Security Camera User Manual


 
EDN850H
27
4.4.2.1 LENS
1. When the SETUP menu is displayed on the screen, please direct the arrow to point
to “LENS” by using the UP and DOWN buttons. Press the SET button to adjust
IRIS level (the higher is brighter). In most cases, you don’t need to adjust this,
since Lens is Auto Iris supported.
2. Please press SET button for saving setting and return to the previous menu.
4.4.2.2 SHUTTER
1. When the SETUP menu is displayed on the screen, please direct the arrow to point
to “SHUTTER” by using the DOWN button.
2. Select the shutter mode by pressing the LEFT or RIGHT button. Three modes are
available: FLK, ESC and Manual.
Ö FLK: Please select “FLK” mode when flickering occurs on the screen, which
is caused by an irregular balance between illumination and frequency. NTSC
model: 1/100, PAL model: 1/120.
SETUP
> LENS DC <┘
SHUTTER ___
WHITE BAL. ATW
BACKLIGHT OFF
AGC MIDDLE
DNR LOW
SENS-UP AUTO
<┘
SPECIAL <┘
EXIT
LENS
> LEVEL |+++++++++| 20
Note:
Since DC lens is a built-in lens for EDN850H camera, shutter does not support ESC and
Manual functions. ESC and Manual are reserved functions, please do not select these
two options in normal situation.
Note:
Since DC lens is a built-in lens for EDN850H camera, it does not support Manual lens,
please do not select lens as Manual mode, it disables sens-up and may cause malfunction
of lens.