Hand Held Products 4X00 Digital Camera User Manual


 
2 - 38 IMAGETEAM™ 4X00 Series Software Development Kit (SDK) User’s Guide
oemGetSetupTelepen
This function is used to get the Telepen symbology specific options.
Result_t oemGetSetupTelepen (
SetupType_t SetupType,
BOOL *pEnabled,
WORD *pMinLength,
WORD *pMaxLength,
BOOL *pOldStyle
)
Return Values
RESULT_SUCCESS
RESULT_ERR_PARAMETER
Parameters
SetupType
SETUP_TYPE_CURRENT for current settings, or SETUP_TYPE_DEFAULT for default settings.
pEnabled
Points to a BOOL variable that contains the enabled state of this symbology upon returning from the function. A TRUE
means the symbology is enabled; a FALSE means the symbology is disabled.
pMinLength
Points to a WORD variable that contains the minimum length decoded Telepen message the engine should return.
Telepen messages smaller than this minimum length are not reported by the engine. The default value is 1.
pMaxLength
Points to a WORD variable that contains the maximum length decoded Telepen message the engine should return.
Telepen messages larger than this maximum length are not reported by the engine. The default value is 60.
pOriginal
Points to a BOOL variable that reflects if the engine is configured to reads Telepen labels that were encoded with either
the original or the AIM specification. The default is FALSE.
oemGetSetupTLC39
This function is used to get the TLC39 symbology specific options.
Result_t oemGetSetupTLC39 (
SetupType_t SetupType,
BOOL *pEnabled
)
Return Values
RESULT_SUCCESS
RESULT_ERR_PARAMETER
Parameters
SetupType
SETUP_TYPE_CURRENT for current settings, or SETUP_TYPE_DEFAULT for default settings.
pEnabled
Points to a BOOL variable that contains the enabled state of this symbology upon returning from the function. A TRUE
means the symbology is enabled; a FALSE means the symbology is disabled.