Hitachi KP-F32F Digital Camera User Manual


 
6
(7) GAMMA (CSR: F0F0-0818 h)
Gamma correction is adjusted.
-OFF-
Setting value 80000000h
Gamma correction is set to OFF.
-Manual adjustment-
Setting value 820000xx h xx: 00h to FFh (Standard 00h)
Adjust the detail gamma.
(8) TRIGGER (CSR: F0F0 0830 h)
Sets external trigger operating mode.
-OFF-
Setting value 80000000h
Trigger function set to OFF.
-Manual adjustment-
Setting value 8xyz0000 h x2- LOW ACTIVE, 3- HIGH ACTIVE (POLARITY)
y0- PORT1, 2- PORT2, E- SOFTTRIGGER (SOURCE)
z0- MDOE0, 1- MODE, 3- MODE3, E- MODE14, F- MODE15 (MODE)
External trigger signal polarity is switched at value x. Trigger source is switched at value y. Trigger mode
is switched at value z.
See "Trigger operation and timing chart" (page 13 to 16).
(9) TRIGGER DELAY (CSR: F0F0 0834 h)
Adjust a gap of few time form noticing trigger pulse to starting exposure.
-OFF-
Setting value 80000000 h
Trigger delay is set OFF.
-Duration of delay adjustment-
Setting value 82000xxx h xxx: 000h to FFFh (standard: 000 h)
Adjust the delay time from 000h (0.4μs) to FFFh (3931.6μs) by 0.96μs steps.
(10) SOFTWARE TRIGGER (CSR: F0F0 0000 h)
Run software trigger.
-ON-
Setting value 82000000 h
-OFF-
Setting value 80000000 h
(11) INITIALIZE (CSR: F0F0 0000 h)
Return equipment to status at time of release from factory.
-Initialization-
Setting value 80000000 h
(12) MEMORY SAVE (EXECUTE) (CSR: F0F0 0618 h)
Make back up of presently effective memory channels.
-BACK UP execute-
Setting value 80000000 h
(13) MEMORY SAVE (Ch SET) (CSR: F0F0 0620 h)
Select channel carried out memory backup.
-channel set-
Setting value x0000000 h x: 1- ch1, 2- ch2, 3- ch3, 4- ch4
OFF
Input
ON
Output