Honeywell Xenon 1500 Photo Scanner User Manual


 
6 - 7
When Check Character is set to Validate and Transmit, the scanner only
reads Code 39 bar codes printed with a check character, and will transmit
this character at the end of the scanned data.
Default = No Check Charac-
ter.
Code 39 Message Length
Scan the bar codes below to change the message length. Refer to
Message Length Description (page 6-2) for additional information. Mini-
mum and Maximum lengths = 0-48. Minimum Default = 0, Maximum
Default = 48.
Code 39 Append
This function allows the scanner to append the data from several Code 39
bar codes together before transmitting them to the host computer. When
the scanner encounters a Code 39 bar code with the append trigger char-
* No Check Character
Validate and Transmit
Validate, but Don’t Transmit
Minimum Message Length
Maximum Message Length