IDEAL INDUSTRIES HeatSeeker 160 Digital Camera User Manual


 
#61-846
ND-7521-1 Page 23 of 25
A3. Technical specification
Performance
Field of View: 20° X 15°
Focus: Manual
Minimum Focus: 30cm
Spectral response: 8µm to 14µm
Thermal Sensitivity: NETD 80mK (0.08°C) @ 23°C ambient and
30°C scene temperature.
Detector: 160×120 Pixels uncooled microbolometer
Measurement
Temperature range: 14 F to +482 F (-10 C to +250 C)
Radiometry: Four moveable temperature measurement cursors giving automatic
temperature difference measurement and auto locking onto hottest and
coldest points
Emissivity Correction: User selectable 0.1 to 1.0 in steps of 0.01 with reflected ambient
temperature compensation. The four measurement cursors can have
individual emissivity values assigned to them.
Accuracy: The greater of ±2 C or ±2% of reading in C for the operating
temperature range of -15 C to +45 C.
Display
3 ½” colour LCD with LED backlight with 8 color palettes
Thermal images or visible images or mixed thermal and visible images including picture in
picture.
Electronic zoom (IR and visible): x2; x4; Image integration: Up to x4
Image Storage
Over 1000 images on supplied micro-SD card
Laser Pointer
A built in Class 2 laser is supplied to highlight the center of the thermal image. (Aligned at 6
feet)
Beam Divergence: <0.2mrad
Maximum Output: <1mW
Imager power Supply
Battery: Rechargeable Lithium-Ion field replaceable battery with up to 5 hours
continuous operation; charge through the USB port
AC Operation: USB AC power adaptor supplied
Mechanical
Housing: Impact resistant plastic with over molded soft plastic.
Dimensions: 130mm X 95mm X 220mm
Weight: 0.8Kg
Mounting: Handheld & tripod mounting
1
/
4
" BSW.
Settings and Controls
Auto/user selectable span and level control.
Readout in °C or °F
Four moveable temperature measurement cursors with individual emissivity values and
temperature difference between two points.
User selectable emissivity setting for each measurement cursor.
Auto hot and cold seeking or hot only or cold only.
User selectable reflected temperature compensation.
Area analysis 3 options.
X-Y thermal profiles.