Installation
2.2.2 (e) Analog Output Connector
The TM-6760 has a BNC connector on the rear panel
to output analog video data.
2.2.3 Shutter Speed Control Dial (TM-6760 only)
Shutter speed can be selected by switching the shutter dial to the
appropriate setting (0 through 9). The factory default settings correspond
to the shutter speeds as shown in below.
2.2.4 RS-232 Communication Cable (TM-6760 only)
FIGURE 5. Serial Communication Cable RS-232B-12
The RS-232 controller set CS-232E includes cable RS-232B-12 interface cable, software disk, and a
quick-start card. The TM-6760 camera’s built-in look-up table (LUT) can be controlled by an external
RS-232 interface. The camera settings can be programmed or changed using the communication cable
and software. Commands from the RS-232 interface will override the rear panel switch settings of the
camera. Please refer to the camera control software manual for details on the graphical user interface.
TABLE 5. Shutter Speed Control Dial
Shutter Exposure Time (Seconds)
Normal Async
0 No shutter (1/60) no shutter (1/60)
1 1/125 1/32,000
2 1/250 1/16,000
3 1/500 1/8,000
4 1/1,000 1/4,000
5 1/2,000 1/2,000
6 1/4,000 1/1,000
7 1/8,000 1/500
8 1/16,000 1/250
9 1/32,000 Ext. pulse width con-
trol