read_only Use LOCK switch is enabled
on Use LOCK switch is disabled
Allowed users admin, operator, user
Setting SD Card to Use/Disable
Format /api/param?storage.disk(1).status=data
Example of Response storage.disk(1).status&200 OK
Interpretation Change the Use/Disable status of SD Card. Specify “on” or “off”. In case of “on”, SD Card can be
use. In case of “off”, SD Card is disabled.
Allowed users admin, operator, user
Getting Status of SD Card formatting
Format /api/param?storage.disk(1).initialize
Example of Response storage.disk(1).initialize=on&200 OK
Interpretation Acquire status of SD Card formatting. “on”, “off”, or “not_initialized” will be returned. In case of “on”,
SD Card formatting is in progress. In case of “off”SD Card is formatted. In case of “not_initialized”, SD Card is
unformatted.
Allowed users admin, operator
Formatting SD Card
Format /api/param?storage.disk(1).initialize=data
/api/param?storage.disk(1).initialize=start
Example of Response storage.disk(1).initialize&200 OK
Interpretation Specify as start to format the SD. When this API is issued, the camera reboots in about 1 minute.
Allowed users admin, operator
Getting SD Card Constant Recording On/Off Status
Format /api/param?application.event(8).status
Example of Response application.event(8).status=on&200 OK
Interpretation Acquire the on/off status of SD Card Constant Recording. “on” or “off”will be returned.
Allowed users admin, operator, user
Setting SD Card Constant Recording On/Off
Format /api/param?application.event(8).status=data
Example of Response application.event(8).status&200 OK
Interpretation Change the on/off status of SD card Constant Recording. Specify "on" or "off" to change the
status.