42
Interpretation Acquire filter setting of the alarm action for the specified alarm number. Up to 5 alarm actions can be
specified, and periodic FTP is assigned to event No.6, therefore the number of alarm(number) can be set between the
range of 1 to 6. Note that alarm numbers are different from the alarm input pin numbers.
Specify sunday, monday, tuesday, wednesday, thursday, friday or saturday for WeekOfDay. When the filter is enabled,
on will be returned. When the filter is disabled, off will be returned.
Allowed users admin, operator
Setting Alarm Filter for VN-V685/686/686B
Format /api/param?application.event(Number).filter(WeekOfDay).status=data
Example When setting Sunday filter of Alarm No. 1
/api/param?application.event(1).filter(sunday).status=on
Example of Response
application.event(1).filter(sunday).status&202
Accepted(application.event(1).status=restart)
Interpretation Set filter setting of the alarm action for the specified alarm number. Up to 5 alarm actions can be
specified, and periodic FTP is assigned to event No.6, therefore the number of alarm(number) can be set between the
range of 1 to 6. Note that alarm numbers are different from the alarm input pin numbers.
Specify sunday, monday, tuesday, wednesday, thursday, friday or saturday for WeekOfDay.
Specify on to enable the filter, off to disable the filter.
The changes to filter of alarm action is saved by /api/param?application.event(Number).status=restart.
Allowed users admin, operator
Getting Alarm Filter Time from VN-V685/686/686B
Format /api/param?application.event(Number).filter(WeekOfDay).time
Example When Getting Time of Sunday filter of Alarm No. 1
/api/param?application.event(1).filter(sunday).time
Example of Response application.event(1).filter(sunday).time=000000-240000&200 OK
Interpretation Acquire filter time of the alarm action for the specified alarm number. Up to 5 alarm actions can be
specified, and periodic FTP is assigned to event No.6, therefore the number of alarm(number) can be set between the
range of 1 to 6. Note that alarm numbers are different from the alarm input pin numbers.
Specify sunday, monday, tuesday, wednesday, thursday, friday or saturday for WeekOfDay. Start time and end time is
returned in the format like hhmmss-hhmmss. Start time can be from 000000 to 235959. End time can be from 000001 to
240000.
Allowed users admin, operator
Setting Alarm Filter Time for VN-V685/686/686B