JVC 686BU Security Camera User Manual


 
88
Format /api/param?network.vsip_server.port
Example of Response network.vsip_server.port=5510&200 OK
Interpretation Acquire port number of VSIP server in VN-V685/686/686B. In VN-V686, this API is not available.
Allowed users admin, operator
Setting Port Number of VSIP for VN-V685/686/686B
Format /api/param?network.vsip_server.port=data
Example of Response network.vsip_server.port&202
Accepted(network.vsip_server.status=restart)
Interpretation Change port number of VSIP server in VN-V685/686/686B. In VN-V686, this API is not available.
Default value is 5510. To validate the change, use "network.vsip_server.status=restart".
Allowed users admin, operator
Getting Status of AMX Discovery Protocol from VN-V685/686/686B
Format /api/param?network.amx.beacon.status
Example of Response network.amx.beacon.status=on&200 OK
Interpretation Acquire status of AMX Discovery Protocol in VN-V685/686/686B. "on" or "off" is returned. In
VN-V686, this API is not available.
Allowed users admin, operator
Setting Status of AMX Discovery Protocol for VN-V685/686/686B
Format /api/param?network.amx.beacon.status=data
Example /api/param?network.amx.beacon.status=on
Example of Response network.amx.beacon.status&200 OK
Interpretation Change status of AMX Discovery Protocol in VN-V685/686/686B. In VN-V686, this API is not
available. Specify "on" for interoperability with AMX products.
Allowed users admin, operator
Getting Mode of JPEG streaming from VN-V685/686B
Format /api/param?network.http(streaming).priority
Example of Response network.http(streaming).priority=clientnumber&200 OK
Interpretation Acquire mode of JPEG streaming. "framerate" or "clientnumber" is returned. This API is available for
VN-V685/686B from v2.00.
Allowed users admin, operator
Setting Mode of JPEG streaming for VN-V685/686B