JVC TK-C655 Security Camera User Manual


 
41
AUTO RETURN Setup
If the camera is not operated at the preset time after it has been operated manually, it will automatically return to the status set
previously.
1
TO CAMERA DATA I / O
RX
RX
+
RX
RX
-
TX
TX
+
TX
TX
-
COM
COM
1 2 3 4 5 6 7 8
COM
COM
9/110/211/312/413/514/615/716/8
COM
COM
COM
COM
COM
COM
CAMERA
CAMERA
SW
UNIT
UN
IT
ALARM
ALARM
AUTO
4312 8756
2 3 4 5 6 7
8
1
MONITOR
MONITOR
OUTPUT
OUTPUT
MONITOR
MONITOR
SERIAL-2
SERIAL-2
SERIAL-1
SERIAL-1
VIDEO INPUT
VIDEO INPUT
VIDEO OUTPUT
OUTPUT
OUTPUT
2
1
ON
2 3 4 5 6 7
8
POWER
OFF
ON
AC INPUT
`
4312 8756
ON
< RM-P2580 rear >
SETUP
MENU SET
SPEED
IRIS
AF
FOCUS
ZOOM
OPEN
FAR
TELE CLEAR
/HOME
7
4
1
8
0
5
2
9
6
3
ENTER
AUTO
PAN
OPTION
1
OPTION
2
CAMERA
POSI-
TION
AUTO
PATROL
CLOSE
NEAR
WIDE
AUTO F-1 F-2 F-3
PAN/TILTLENS
CAMERA/POSITION
CAMERA POSITION
REMOTE CONTROL UNIT
RM-P2580
ALARM
POWER
KEY LOCK
PAN/TILT
lever
CAMERA
buttons
ENTER button
SET button
MENU button
SETUP menu display on the camera
CAM. FUNCT ION1 . .
CAM. FUNCT ION2 . .
–––MENU–––
CAM. TITLE/ALARM. .
CAM. VIDEO ADJUST. .
CAM. ALC. .
HOME MOTION DETECT . .
AUTO PAN/PATROL/TRACE. .
POSI .FUNCTION SET. .
FACTORY SETTINGS. .
CAMERA FUNCTION2 screen
AF FOR IR OFF
–––CAMERA FUNCTION2
– – –
AUTO RETUR NOFF
RETUR NT I M E
– – –
*Before setting AUTO RETURN, make sure to set the
rear panel DIP Switch of RM-P2580.
1. Turn off the power of RM-P2580.
2. Set rear DIP Switch4 of RM-P2580 to “ON”.
3. Turn on the power of RM-P2580 again.
1.
Display the SETUP menu on the camera.
(
P.20, steps 1 to 4)
MENU button(3sec) A Select “CAMERA” with the PAN/TILT lever
A SET button.
2.
Display the CAMERA FUNCTION2 screen.
Tilt the PAN/TILT lever up or down to move the cursor (>) to “CAM-
ERA FUNCTION2” and press the SET button.
The CAMERA FUNCTION2 screen is displayed.
3.
Set the return status using AUTO RETURN function.
Set the status for the camera to return to automatically when it is not
operated for a certain time.
Setting values: OFF, HOME, A.PAN KEY, A.PATROL KEY
4.
Set the time for AUTO RETURN to activate.
Selectable time: 1 min, 2 min, 3 min, 5 min, 10 min, 20 min, 30
min, 60 min
When “AUTO RETURN” is set to “OFF”, “---” will be displayed and
setting will be disabled.
5.
Press the MENU button.
The screen returns to the MENU screen.
During MENU setting and alarm operation, it will not return to the status set
under AUTO RETURN.
After the alarm operation, it will return to the status set under AUTO RE-
TURN.
When using AUTO RETURN function, make sure to use the REMOTE CON-
TROL UNIT of the product with model name RM-P2580(A) as on the serial
number plate. RM-P2580 without (A) will not function properly.
MEMO