Mace CAM91 Security Camera User Manual


 
Operating Your Camera
34
Day&Night Color CCD Camera
35
Day&Night Color CCD Camera
Using Remote Jack
Reset
This function resets the camera to the default setting preset at the factory.
1. Press the SET button to display the Setup menu and move the arrow indicator
to ‘Reset’ using the UP or DOWN button.
2. In the confirmation mode, select ‘YES’ or ‘NO’ If ‘YES’ selected, all modes are
initialized and return to the default status.
End
Press the SET button to display the setup menu and move the arrow indicator to
‘END’ using the UP or DOWN button. Then you are finished on Setup.
If you connect a remote plug to the REMOTE jack on the rear on the camera as
shown below, you can access the menu setup mode from a remote place with an
equipment like computer
1. RS-232C Communication Setting
Mode : Serial Data bit : 8
Bit/sec.: 9600bps Stop bit : 1
Parity : None
2. Wiring
3. Setup menu Command
Setup
Camera ID
BLC
Lens
Shutter
Gain
White Balance
Motion Detect
Color
Sync.
Reset
End
OFF
OFF
DC
OFF
AGC
ATW
OFF
AUTO
L / L
Select YES or NO using the LEFT
or RIGHT button
Are you sure YES
Press SET button
If there’s no button control at Menu over 30 sec., the setup is automatically finished with
automatic update of the controlled menu by that time. However there is no time limit at
Subsidiary Menu.
Setup menu
SET
UP
DOWN
LEFT
RIGHT
Command
0A, 02, 01, 00, 00, AF
0A, 02, 02, 00, 00, AF
0A, 02, 03, 00, 00, AF
0A, 02, 04, 00, 00, AF
0A, 02, 05, 00, 00, AF
Byte
6
6
6
6
6
REMOTE
GND (Grounding Terminal)
Tx (Transmit Data)
Rx (Receive Data)
Remote Control on Setup