Metz 44 MZ-2 Camera Flash User Manual


 
86
ķ
16. Troubleshooting
Should the LC display indicate meaningless information or should the flash
unit not work properly in the individual modes, then switch off the mecablitz
for about 10 seconds by its main switch. Check the camera settings and find
out if the flash unit’s foot is correctly mounted in the camera’s accessory shoe.
The mecablitz must operate properly when it is switched on again. Contact
your local dealer should this not be the case.
17. Maintenance and care
Remove any grime and dust with a soft, dry or silicon-treated cloth. Never
use detergents that could damage plastic parts.
Forming the flash capacitor
The flash capacitor incorporated in the flash unit undergoes a physical change
when the flash unit is not switched on for prolonged periods of time. For this
reason it is necessary to switch on the mecablitz for approx. 10 minutes every
3 months (see Chapter 2.4). The batteries must supply sufficient power for flash
readiness to be indicated within 1 minute after the mecablitz was switched on.
18. Technical data
Max. guide number at ISO 100 / 21°; zoom 105
mm:
Metric system: 44 Imperial system (ft): 144
Flash modes:
• TTL
• Automatic (12 auto aperture at ISO 100 / 21°):
f/1 - f/1.4 - f/2 - f/2.8 - f/4 - f/5.6 - f/8 - f/11 - f/16 - f/22 - f/32 - f/45
• Manual (8 partial light output levels)
Sensor coverage angle:
approx. 25°
Flash durations:
approx. 1/200 s... 1/20000 s in TTL mode
In manual flash mode M:
• at 1/1 (full) light output approx. 1/200 s
• at 1/2 light output approx. 1/600 s
• at 1/4 light output approx. 1/1500 s
• at 1/8 light output approx. 1/3000 s
• at 1/16 light output approx. 1/5000 s
• at 1/32 light output approx. 1/8000 s
• at 1/64 light output approx. 1/13000 s
• at 1/128 light output approx. 1/20000 s
• at 1/256 light output approx. 1/26000 s
Colour temperature:
approx. 5600 K
Film speed:
ISO 6 to ISO 6400
Synchronisation:
Low voltage ignition