NEC IS010-12E Digital Photo Frame User Manual


 
Chapter 2 Message List
487
iSM14414: Forced Reduce(maintenance) :
RANK=<aa>h, PDN=<bb>h,
PDG=<cc>h, status=<ddd...d>
[Classification] INFO
[Explanation] It indicates that forced reduce was instructed to specified physical disk.
aa : RANK number
bb : Physical disk number
cc : PD group number
ddd...d : Execution state of the command.
good : Normal
failed(xxxx) : Error occurred (xxxx is error description)
[Measures] When an error occurs (status=failed was output), the configuration or setting of
the disk array may be changed. After updating it to the newest information or
restarting state monitoring, check current state and execute again.
iSM14415: Preventive Reduce(maintenance) :
RANK=<aa>h, PDN=<bb>h,
PDG=<cc>h, status=<ddd...d>
[Classification] INFO
[Explanation] It indicates that preventive replacement was instructed to specified physical disk.
aa : RANK number
bb : Physical disk number
cc : PD group number
ddd...d : Execution state of the command.
good : Normal
failed(xxxx) : Error occurred (xxxx is error description)
[Measures] When an error occurs (status=failed was output), the configuration or setting of
the disk array may be changed. After updating it to the newest information or
restarting state monitoring, check current state and execute again.