344 Technical Notes
Shutter
Type Electronically-controlled vertical-travel focal-
plane shutter
Speed
1
/
4000 – 30 s in steps of
1
/
3 EV; Bulb; Time
Flash sync speed X=
1
/
200 s; synchronizes with shutter at
1
/
200 s or
slower
Release
Release mode 8 (single frame), I (continuous), J (quiet
shutter release), E (self-timer), "(delayed
remote; ML-L3), # (quick-response remote; ML-L3)
Frame advance rate Up to 5 fps
Note: Frame rates assume manual focus, manual or
shutter-priority auto exposure, a shutter speed of
1
/
250 s or faster, and other settings at default
values.
Self-timer 2 s, 5 s, 10 s, 20 s; 1–9 exposures
Exposure
Metering mode TTL exposure metering using 420-pixel RGB
sensor
Metering method Matrix metering: 3D color matrix metering II (type
G, E, and D lenses); color matrix metering II
(other CPU lenses)
Center-weighted metering: Weight of 75% given to
8-mm circle in center of frame
Spot metering: Meters 3.5-mm circle (about 2.5%
of frame) centered on selected focus point
Range (ISO 100, f/1.4
lens, 20 °C/68 °F)
Matrix or center-weighted metering: 0–20 EV
Spot metering: 2–20 EV
Exposure meter
coupling
CPU