Panasonic AK-HBU931P Digital Camera User Manual


 
: Cable clamp
This is used to clamp the optical fiber cable from the
CCU.
; Optical fiber connector
< AC outlet
An AC output of up to 200 VA can be supplied to this
outlet.
= AC outlet circuit-breaker
This is the circuit-breaker for the AC outlet. If the AC
output load is too high and the circuit breaker has been
tripped, reduce the load, and then reset the circuit
breaker by pressing the circuit breaker button.
> Power main circuit breaker
This is the main circuit-breaker for the unit's power
supply. If the circuit breaker has been tripped by an
overcurrent or for some other reason, check the cause,
take the appropriate measures to remedy the problem,
and then reset the circuit breaker by pressing the circuit
breaker button.
? AC OUTLET reset switch
This cuts off the AC output when it drops below the
minimum voltage that can be supplied. When this has
happened, the outlet can be reset by pressing this reset
switch without turning off the camera's power.
@ AC OUT alarm display
This lights when the AC output voltage range exceeds 10%.
6
Controls and their functions
Left Side Panel Operation panel
1 VF power switch [VF POWER]
This is used to set the viewfinder’s power to ON or OFF.
When it is lighted, the viewfinder’s power is OFF.
2 Front tally ON/OFF switch [FRONT TALLY]
This is used set the viewfinder and lens tally lamp to ON
or OFF. When the lamp is lighted, the tally lamp is OFF.
3 CENTER marker switch [CENTER MARKER]
This is used to set the center marker to ON or OFF.
4 CURSOR switch
This is used to set the cursor on the viewfinder screen to
ON or OFF. When it is lighted, the cursor is OFF.
5 Cursor memory switch 1
If this switch is held down while the cursor switch is ON,
the current cursor status is stored in the memory. If the
cursor switch is set to ON after the cursor memory switch
1 has been pressed, the cursor which was stored in the
memory by the cursor memory switch 1 can be called.
6 Cursor memory switch 2
If this switch is held down while the cursor switch is ON,
the current cursor status is stored in the memory. If the
cursor switch is set to ON after the cursor memory switch
2 has been pressed, the cursor which was stored in the
memory by the cursor memory switch 2 can be called.
7 H-POSI control [H-POSI]
This is used to adjust the horizontal position of the
cursor.
8 V-POSI control [V-POSI]
This is used to adjust the vertical position of the cursor.
9 Width control [WIDTH]
This is used to adjust the width of the cursor.
: Height control [HEIGHT]
This is used to adjust the height of the cursor.
=
>
?@
A
B
C
1
2
3
4
5
6
78
9
;:<
D
E
F
G
H
I
JK
L
ALARM
OUT(200VA)AC
BREAKER
MAIN
12OV
AC 80Hz
RESET
CCU
<?
; :
=
>
@
Pin No.
1
2
3
4
5
6
Function
Optical fiber
Optical fibe
Control wire, hot
Control wire, cold
AC 240V live
AC 240V neutral
Polarity
+
+
Signal flow
CAM#CCU
CCU#CAM
CAM!#CCU
CAM!#CCU
CCU#CAM
CCU#CAM
OPT FIBER connector (EDW.3K.93C.CLC made by LEMO)