- 10 (E) -
ENGLISH
HD SDI output connector [HD SDI OUT]
SDI signal output is given by this line.
G/L input connector [G/L IN]
For gen-lock with the camera, the external sync signal (black burst) or tri-level sync
signal is supplied to this input connector.
Cable clamp
Clamp the DC power supply cable connected to the DC 12 V input connector to
prevent it from slipping out.
Optional card slot
Slot for inserting an optional card. For details, refer to the manual for optional cards.
Cooling fan
• Do not block or obstruct the ventilation during operation. It may otherwise cause
internal heating or fire.
• The life of this fan is approximately 50,000 hours (at room temp. 77°F (25°C)).
Replace the fan as needed.
(When the room temperature is higher than 95°F (35°C), replace the fan 30% earlier.)
Be sure to ask the dealer for the replacement.
Interface connector [I/F]
Pin No. Signal
1 Gen-lock signal GND
2 Time code signal input
3 Not used
4 TX_N (EIA422)/TXD (EIA232) output
5 RX_N (EIA422)/RXD (EIA232) output
6 Camera power supply input (DC +12 V)
7 Gen-lock signal input
8 GND
9 TX_P (EIA422) output
10 RX_P (EIA422) input
11 GND
12 Time code signal GND
13 GND
14 GND
15 GND
Major operating controls and their functions
5
1
6
10
15
11