Panasonic BM-ET500 Digital Camera User Manual


 
15
ADJUSTMENTS AND MAINTENANCE
Adjustment
Adjusting the Buzzer Level
Adjust the buzzer level, which informs you of recognition
results, as follows.
1. Open the cover of the numeric keyboard.
2. Insert a Phillips precision screwdriver into the buzzer-
level adjustment hole.
3. Turn the screwdriver to the right or left to adjust the
buzzer level.
To the right: The volume will go up.
To the left: The volume will go down.
Maintenance
Replacing the Front Panel
When the supplied front panel has been damaged, you can
replace it to a new one.
1. Remove the numeric keyboard. (Refer to p.12.)
2. Remove the front panel, and then replace it to a new
one.
You can take the panel away by sliding down.
During the replacement, wear gloves on your hand to
keep the new panel clean.
3. When finished, connect the control cable to the numeric
keyboard.
Cleaning the Inside of the Camera Unit
There are a mirror, proximity sensor, and two cameras
inside the unit. The cameras will be used for capturing a
face and irises. If dust is sticking to the cameras, it may
cause malfunction. Clean the inside of the camera unit as
follows.
1. Remove the numeric keyboard and the front panel.
(Refer to p.12 and this page.)
2. Blow dust away from the mirror, sensor, Camera 1 and
Camera 2 by using a blower, etc.
If dust still sticks after blowing, wipe away the appli-
ances gently with an eyeglass cleaner or a camera-lens
cleaner.
3. After finished, attach the front panel and numeric key-
board to the unit.
Notes:
Keep your hands away from the mirror, Camera 1
and Camera 2. If you touch them directly, it may
cause malfunction due to smudges.
Do not clean the camera unit with a glass-cleaner,
thinner or water. It may cause malfunction.
Clean the camera unit with delicate care. Force may
damage the appliance, which may cause trouble.
1 2 3 4 5
6 7 8 9 0
CANCEL
ENTER
Buzzer-level
adjustment hole
Volume down Volume up
Make sure the panels
correct side.
Bottom
Mirror
Sensor
Camera 2
Camera 1